SUP-LZ Metal Tube Rotameter is a device that measures the volumetric flow rate of fluid in a closed tube. It belongs to a class of meters called variable-area flowmeters, which measure flow rate by allowing the cross-sectional area the fluid travels through to vary, causing a measurable effect.
Product | Metal Tube Rotameter |
Model | SUP-LZ |
Range | Water (20℃) (01~200000) L/h Air (20,0.1013MPa) (0.03~3000) m³/h |
Range ratio | Standard 10:1 Optional 20:1 |
Accuracy | Standard: 1.5% Optional:1% Gas: 1.5% |
Pressure |
standard:DN15~DN50≤4.0MPa DN80~DN200≤1.6MPa Optioanl: DN15~DN50≤32MPa DN80~DN200≤16MPa |
Connection | Flange, Clamp, Thread, Sanity thread |
Medium temperature |
Standard: -20℃~120℃ PTFE 0℃~80℃ High temp: 120℃~450℃ low temp: -80℃~-20℃ |
Environment temperature |
Remote type: -40℃~85℃ Pointer type/local alarm type -40℃~100℃ |
Power supply |
Standard type: 24VDC two-wire system (4-20) mA (12VDC~32VDC) Alarm type: 24VDC multi-wire system (4-20) mA (12VDC~32VDC) AC type: (100~240) VAC 50Hz~60Hz Battery type: 3.6V@9AH lithium battery |
Load resistance | RLmax: 600Ω |
Alarm Output |
Upper and lower limit instantaneous flow alarm Local alarm type: upper limit, lower limit or upper and lower limit instantaneous flow alarm (Contact capacity 1A@30VDC) Upper limit and lower limit alarm hold range is a maximum of 60% of range, and the minimum interval between upper and lower limit alarms is 10% of range |
Pulse output | Cumulative pulse output is output of optocoupler signal isolation Darlington tube (internal 24VDC power supply, maximum current 8mA) |
Ingress protection | IP65 |
A metal tube Rotameter is a type of flow meter that measures the flow rate of a fluid, typically a gas or a liquid. It consists of a tapered metal tube, a float, and a scale. The tapered metal tube has a larger diameter at the bottom and gradually narrows towards the top. The float is a small metallic ball or cylinder that moves freely up and down inside the tube. The scale is marked with flow rate graduations and is attached to the outside of the tube.
The operation of a metal tube Rotameter is based on the principle of buoyancy. When fluid flows through the metal tube, the float rises or falls to a position where the force of the fluid flow is equal to the gravitational force acting on the float. The position of the float corresponds to the flow rate of the fluid, and this can be read off the scale. As the flow rate increases, the float rises and the reading on the scale increases. Conversely, as the flow rate decreases, the float falls and the reading on the scale decreases.
Metal tube Rotameters are commonly used in process industries to measure the flow of gases and liquids in pipes. They are simple and reliable, and can be used to measure a wide range of flow rates. However, they are not suitable for measuring very low flow rates or highly viscous fluids.
The SUP-LZ metal tube Rotameters are easy to install and maintain, with a simple design that requires minimal calibration and maintenance. They are also easy to read, with a clear scale that allows operators to quickly and accurately determine the flow rate.
The thermal mass flow meter is designed based on the principle of thermal diffusion. The instrument uses the constant temperature difference method to accurately measure the gas. It has the advantages of small size, high degree of digitization, convenient installation and accurate measurement. Reduce your energy costs and increase your sustainability. Monitor your consumption and analyze your leakage flows with just one measuring device.
Learm MoreMass Flow Meter is a new type of advanced flow measurement instrument and has been rapidly developed in the world. It has been widely used for process detection and custody transfer measurement in many industries such as petroleum, petrochemical, chemical, pharmacy, marine, pharmaceutical, municipal, paper, food and energy and so on. It has been highly valued by the flow research community and welcomed by users at home and abroad.
Learm MoreSUP-1158S Wall mounted clamp on ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
Learm MoreSUP-2100H ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
Learm MoreAfter a long time of use, the parts in the flowmeter will be friction and wear, resulting in performance degradation and affecting the accuracy of measurement.
Read MoreThe usage methods of Famet turbine flowmeter for liquid turbine flowmeter mainly include start-up operation, shutdown operation, and maintenance.
Read MoreElectromagnetic flowmeter is an instrument that measures liquid flow rate through the principle of electromagnetic induction, consisting of a flowmeter body and electrodes.
Read MoreHangzhou Economic Development Area,Hangzhou 310018,China