During the use of vortex flow meters, users often encounter problems such as unstable and irregular signal output or unstable instantaneous flow.
During the use of vortex flow meters, users often encounter problems such as unstable and irregular signal output or unstable instantaneous flow. If you encounter such problems, you can check the following points:
1. First check whether the medium flow rate in the pipeline exceeds the measurable flow range of the sensor;
2. If the medium flow rate is within Within the measurable range, check whether the front and rear straight pipe sections meet the requirements, and confirm whether the medium in the pipeline is in a stable flow state, and there is no two-phase flow or pulsating flow in the pipeline;
3. Check whether the vibration intensity of the pipeline is excessive If it is too large, you can install a pipeline support point 2D downstream of the flow meter; on the premise of meeting the straight pipe requirements, install a hose transition;
4. Check whether there are strong electrical interference signals around the instrument, and if so, strengthen shielding and grounding;
5. Check whether the sensor is contaminated, damp, damaged, or has poor lead contact. , if necessary, please clean or replace the sensor and tighten the lead;
6. Check whether the sensor is installed concentrically or whether the sealing gasket protrudes into the pipe. If there is any installation problem, adjust the inner diameter of the gasket;
7. Check the sensitivity of the sensor and adjust the sensitivity;8. Check whether the process flow is stable and adjust the installation position;
9. Check whether there is any entanglement on the generator;
10. Check whether there is cavitation in the pipe. If the flow rate is reduced, increase the pressure in the pipe.
If the user's technical personnel cannot solve the related problems, they can consult the vortex flowmeter manufacturer. Supmea Instruments is a professional vortex flowmeter manufacturer. It has been engaged in the research, development and sales of thermal energy metering and monitoring systems, flowmeters, pressure instruments and regulating instruments for many years, and has undertaken the establishment of internal energy management systems for enterprises. It also has an instrument research and production base with complete infrastructure, reliable technicians, advanced testing methods, and reliable product after-sales service. Digital vortex flow meters, electromagnetic/ultrasonic flow meters, balance flow meters, flow totalizers, prepaid metering systems and other related technical exchanges are welcome to leave messages/consultations.
The thermal mass flow meter is designed based on the principle of thermal diffusion. The instrument uses the constant temperature difference method to accurately measure the gas. It has the advantages of small size, high degree of digitization, convenient installation and accurate measurement. Reduce your energy costs and increase your sustainability. Monitor your consumption and analyze your leakage flows with just one measuring device.
Mass Flow Meter is a new type of advanced flow measurement instrument and has been rapidly developed in the world. It has been widely used for process detection and custody transfer measurement in many industries such as petroleum, petrochemical, chemical, pharmacy, marine, pharmaceutical, municipal, paper, food and energy and so on. It has been highly valued by the flow research community and welcomed by users at home and abroad.
SUP-1158S Wall mounted clamp on ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
SUP-2100H ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
Hangzhou Economic Development Area,Hangzhou 310018,China