What should I do if the measurement error is large when measuring saturated steam vortex flowmeter? You can refer to the following points.
What should I do if the measurement error is large when measuring saturated steam vortex flowmeter? You can refer to the following points:
1. First check whether the power supply voltage of the flow meter is too high;
2. Check whether the zero drift or range adjustment of the analog conversion circuit of the meter is correct. If any Please correct the zero point and span scale;
3. Check whether the medium flow in the pipeline exceeds the measurable flow range of the sensor;
4. If the medium flow is within the measurable range, check before and after Check whether the straight pipe section meets the requirements, and confirm whether the medium in the pipe is in a stable flow state, and there is no two-phase flow or pulsating flow in the pipe;
5. Check whether the sensor is contaminated, damp, damaged, or the leads are in contact Defective, if so, please clean or replace the sensor and tighten the lead;
6. Check whether the instrument has exceeded the calibration cycle;
7. Check whether there is leakage in the pipeline.
Measure saturated steam flow meter, steam prepayment management system, smart heating network management system, vortex flow meter, electromagnetic flow meter, ultrasonic flow meter, balance flow meter, intelligent flow totalizer, prepayment For technical exchanges on metering monitoring terminals and other related technologies, please leave a message for consultation.
The thermal mass flow meter is designed based on the principle of thermal diffusion. The instrument uses the constant temperature difference method to accurately measure the gas. It has the advantages of small size, high degree of digitization, convenient installation and accurate measurement. Reduce your energy costs and increase your sustainability. Monitor your consumption and analyze your leakage flows with just one measuring device.
Mass Flow Meter is a new type of advanced flow measurement instrument and has been rapidly developed in the world. It has been widely used for process detection and custody transfer measurement in many industries such as petroleum, petrochemical, chemical, pharmacy, marine, pharmaceutical, municipal, paper, food and energy and so on. It has been highly valued by the flow research community and welcomed by users at home and abroad.
SUP-1158S Wall mounted clamp on ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
SUP-2100H ultrasonic flow meter uses advance circuit design,coupled with excellent hardware designed in English and can be switched surfaces.It is easy to operate and with stable performance.
Hangzhou Economic Development Area,Hangzhou 310018,China